Test 2020-05-07-18-3 (AASHTO T96-02r10) Summary

Project Information
Project IdentifiersProject ID: 212899
DEA: 051C6704
EFIS: 0512000194
DIST-CO-RTE-PM05-SCR-17-0.2-0.5
Work DescriptionPASATIEMPO RETAINING WALL -
Location DescriptionIN SANTA CRUZ FROM 0.5 MILE TO 0.3 MILES SOUTH OF PASATIEMPO OVERCROSSING
Sample Information
Sample Taken Date5/7/2020 Sample Unique Key18
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing5/29/2020
Sample typeVerification A brief description of the sampleBags of Aggregate
The quantity of what the sample constitutesOne JMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byDoug Last name of sampler or witnessed byLemon
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameGraniterock Aromas Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)Unknown
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collected91-35-0012
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown JMF Verification ID JMF3513-2020-142
Test Details
DIME Sample ID: 2020-05-07-18
DIME Test ID: 2020-05-07-18-3
Testing Lab: CT D05 - Field Laboratory
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Test Release Date: 2020-06-17
Test Results

Input Type: Calculated
Tester's full name: QC
Date of test: 05/19/2020
Grading designation: C
Percent loss after 100 revolutions:9 %
Percent loss after 500 revolutions:36 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 06/17/2020