Test 2020-05-29-28-5 (ASTM D4791-10) Summary

Project Information
Project IdentifiersProject ID: 214731
DEA: 051M0004
EFIS: 0519000047
DIST-CO-RTE-PM05-SLO-101-16.5/R21.5
Work DescriptionCOLD PLANE AND RHMA-GAP GRADED OVERLAY ON EXISTING ROADWAY.
Location DescriptionSAN LUIS OBISPO COUNTY IN AND NEAR PISMO BEACH FROM 0.1 MILE SOUTH OF PRICE CANYON ROAD TO SAN LUIS CREEK BRIDGE
Sample Information
Sample Taken Date5/29/2020 Sample Unique Key28
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing6/10/2020
Sample typeVerification A brief description of the sampleBags of Aggregate
The quantity of what the sample constitutesOne JMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byNoah Last name of sampler or witnessed byHunt
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility namePapich Paso Robles Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-10-0006
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedAt the Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown JMF Verification ID JMF3513-2020-140
Test Details
DIME Sample ID: 2020-05-29-28
DIME Test ID: 2020-05-29-28-5
Testing Lab: CT D05 - Field Laboratory
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Test Release Date: 2020-06-16
Test Results

Method A - Percentage of Flat Particles, Elongated Particles, and Flat & Elongated Particles
Method B - Flat & Elongated Particles

Method: A
Determination: By Mass
Dimensional ratio used: 5:1
Input Type: Calculated
Tester's full name: Daniel Gingras
Date of test: 06/15/2020
Weighted percentage of particles (by mass) that were flat:0 %
Weighted percentage of particles (by mass) that were elongated:0 %
Weighted percentage of particles (by mass) that were both flat and elongated:0 %
Weighted percentage of particles (by mass) that were neither flat nor elongated:100 %
General comments (publicly viewable) (Max 250 characters):

Test was verified on 06/16/2020