Summary for Test 2020-04-16-28-1
Test performed: CTM 643-April 2020Project Information
Project Identifiers | Project ID: 212498 DEA: 021H5204 EFIS: 0217000009 |
---|---|
DIST-CO-RTE-PM | 02-SIS-3,263-48.5/49.7 - 49.41 |
Award Date | 06/09/2023 |
Closeout Date | Not set |
Work Description | Roadway Rehabilitation |
Location Description | 02-Sis-3, 263-R46.8/R48.0, 49.07/49.41 |
QA Service Level | 1 (Verified on 06/06/2017) |
Sample Information
Sample Taken Date | 04/16/2020 | Sample Unique Key | 28 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/16/2020 |
Sample type | Preliminary | A brief description of the sample | Soil |
The quantity of what the sample constitutes | Culvert Recommendation | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Dan | Last name of sampler or witnessed by | Curran |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | D78397 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | In Situ | Transportation Laboratory (TL) Number | 002549 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Unknown |
---|---|---|---|
The fabricator/manufacturer designation for the sample | Unknown | A detailed description of where the material sample was collected | C-7 |
Where the material sample would have been placed if not sampled | Unknown |
Test Details
DIME Sample ID: 2020-04-16-28
DIME Test ID: 2020-04-16-28-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2020-06-18
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Measured
Tester's full name: Darrell Valasek
Date of test: 04/16/2020
Minimum soil resistance of the lab measurement: 3175 Ohms
Soil sample temperature: 19.8 C
Soil box constant: 1
pH of soil: 6.76
Minimum soil resistance corrected to 15.5: 3516.31 Ohm-cm
Minimum soil resistivity at 15.5: 3516 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/18/2020 ✔