Summary for Test 2020-05-01-1-1
Test performed: ASTM A775-07b-re14Project Information
Project Identifiers | Project ID: 214190 DEA: 024G41U4 EFIS: 0218000047 |
---|---|
DIST-CO-RTE-PM | 02-SIS,SIS-5-Var |
Award Date | 08/26/2019 |
Closeout Date | 11/24/2021 |
Work Description | REPLACE REINFORCED CONCRETE BRIDGES & CONSTRUCT RETAINING WALL. |
Location Description | SHASTA AND SISKIYOU COUNTIES ABOUT 7 MILES NORTH OF POLLARD FLAT FROM 0.8 MILE SOUTH TO 0.7 MILE NORTH OF SIMS ROAD UNDERCROSSING AND FROM 0.6 MILE SOUTH OF CASTLE CRAGS DRIVE UNDERCROSSING TO 0.2 MILE SOUTH OF SOUTH DUNSMUIR UNDERCROSSING |
QA Service Level | 1 (Verified on 07/09/2019) |
Sample Information
Sample Taken Date | 05/01/2020 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/07/2020 |
Sample type | Acceptance | A brief description of the sample | #4 ASTM A775 Epoxy Coated Rebar |
The quantity of what the sample constitutes | 881lbs | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Muser |
Title of sampler | QA | Telephone number of sampler | 9165170532 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Western Coatings | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S19-110-20 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM7 - Epoxy Coated Rebar | Rebar Heat Number(s) | 067720 |
---|---|---|---|
Rebar Epoxy Batch Number(s) | 3CH1936010 | Rebar Coating Specification | ASTM A775 |
Rebar Size (#) | 4 | Rebar Coating Color | Green |
Rebar Manufacturer | Cascade | Rebar Coater | Western Coating Eugene OR |
Rebar Powder Manufacturer | Valspar | Release Number | 45854 |
Quality Assurance Code | Unknown |
Test Details
DIME Sample ID: 2020-05-01-1
DIME Test ID: 2020-05-01-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)
Test Release Date: 2020-05-11
Test Results
Input Type: Measured
Tester's full name: Fred Saylor
Date of test: 05/07/2020
Total Number of Holiday: 0
Total Length: 30
Holidays Per Linear Foot of Bar: 0
Holiday Test Pass/Fail: Pass
Bend Test Pass/Fail: Pass
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/11/2020 ✔