Test 2020-04-16-16-1 (CTM 202-November 2011) Summary

The test has been saved successfully.
Project Information
Project IdentifiersProject ID: 3825
DEA: 07138204
EFIS: 0700000142
DIST-CO-RTE-PM07-LA-47,103-3.5/4.6,0.0/1.1
Work DescriptionREPLACE STEEL BRIDGE WITH CIP PS CONCRETE BOX GIRDER BRIDGE AND RAMPS.
Location DescriptionLOS ANGELES COUNTY IN LONG BEACH AND LOS ANGELES ON ROUTE 47 FROM OCEAN BOULEVARD TO ROUTE 103 JUNCTION AND ON ROUTE 103 FROM ROUTE 47 JUNCTION TO ANAHEIM STREET OVERHEAD
Sample Information
Sample Taken Date4/16/2020 Sample Unique Key16
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing4/17/2020
Sample typeAcceptance A brief description of the sampleWCS for PCC Aggregate Acceptance
The quantity of what the sample constitutes40 yrds From where was the sample collectedFabricator
First name of sampler or witnessed byTuan Last name of sampler or witnessed byNguyen
Title of samplerMREA Laboratory sample identification9839
The fabricator/manufacturer/facility nameNational Artesia Transportation Laboratory (TL) NumberTNT1
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)00-00-0000
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedNA
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/8 inch
The concrete mix design numberS75133 Lot numberUnknown
Sublot numberUnknown HMA Design ID
Test Details
DIME Sample ID: 2020-04-16-16
DIME Test ID: 2020-04-16-16-1
Testing Lab: CT - Southern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2020-04-29
Test Results

What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Input Type: Calculated
Tester's full name: Husni Ankir and Larry Diaz
Date of test: 04/23/2020
Cumulative percent passing the 3/8 in. sieve:100 %
Cumulative percent passing the #4 sieve:96 %
Cumulative percent passing the #8 sieve:82 %
Cumulative percent passing the #16 sieve:66 %
Cumulative percent passing the #30 sieve:46 %
Cumulative percent passing the #50 sieve:25 %
Cumulative percent passing the #100 sieve:10 %
Cumulative percent passing the #200 sieve:3.8 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 04/29/2020