Test 2020-04-22-4-3 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 214923
DEA: 081L7104
EFIS: 0820000141
DIST-CO-RTE-PM08--91-
Work DescriptionBridge Repair
Location DescriptionNot set
Sample Information
Sample Taken Date4/22/2020 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing4/23/2020
Sample typeQuality Control A brief description of the sampleMechanical Couplers
The quantity of what the sample constitutesLot 1 From where was the sample collectedFabricator
First name of sampler or witnessed byDavid Last name of sampler or witnessed byWeeks
Title of samplerASI Laboratory sample identification
The fabricator/manufacturer/facility nameIntegrity Rebar Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL79-018-20 Structure unique identifier
Structure nameBuchanan St OC
Material Information
Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerGerdau
Coupler ManufacturerBarSplice Intermediate Assembler or FabricatorIntegrity Rebar
Rebar Size#11 Coupler ModelZap Screwlok Type 2
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterNA Rebar Hoop FabricatorNA
Coupler Component Heat/Lot Number(s)MM19103710 Code A188 Rebar Heat Number(s)65028581
Rebar Size 2 11
Test Details
DIME Sample ID: 2020-04-22-4
DIME Test ID: 2020-04-22-4-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2020-04-23
Test Results

Number of Samples Tested: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 04/23/2020
UTM:2000kip
Temperature:72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
13No. 11/36mm101.5614906295553Service Splicebewing

General comments (publicly viewable) (Max 250 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 04/23/2020