Test 2020-04-14-12-1 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 210837
DEA: 080J0804
EFIS: 0800000283
COOP: 081625
DIST-CO-RTE-PM08-RIV-15-34.7/51.6
Work Description(Alternative Delivery) DESIGN-BUILD OF THE INTERSTATE 15 EXPRESS LANES PROJECT
Location DescriptionRiverside County and SBD-15-0.0/1.3
Sample Information
Sample Taken Date4/14/2020 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing4/20/2020
Sample typeQuality Assurance A brief description of the sampleCouplers
The quantity of what the sample constitutes150 From where was the sample collectedFabricator
First name of sampler or witnessed byWei Jen Last name of sampler or witnessed byLee
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameBarSplice Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCascade Steel
Coupler ManufacturerBarSplice Intermediate Assembler or FabricatorUnknown
Rebar Size#6 Coupler ModelGripTwist
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)A184728 A193034 Rebar Heat Number(s)132019 131819 149419
Rebar Size 2
Test Details
DIME Sample ID: 2020-04-14-12
DIME Test ID: 2020-04-14-12-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2020-04-21
Test Results

Number of Samples Tested: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 04/20/2020
UTM:400kip
Temperature:72.00 f
Halo ID:Small
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11No. 6/19mm1-0.00140.444164294642Service Splicebewing

General comments (publicly viewable) (Max 250 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 04/21/2020