Test 2019-12-18-25-1 (CTM 202-November 2011) Summary

Project Information
Project IdentifiersProject ID: 210735
DEA: 071193U4
EFIS: 0713000007
DIST-CO-RTE-PM07-LA-10-37.2/42.4
Work DescriptionCONSTRUCT HOV LANES, WIDEN BRIDGES, AND REALIGN RAMPS.
Location DescriptionIN LA COUNTY FROM CITRUS STREET IN WEST COVINA TO ROUTE 57 IN POMONA
Sample Information
Sample Taken Date12/18/2019 Sample Unique Key25
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/27/2019
Sample typeAcceptance A brief description of the sample1" AGGREGATE PCC
The quantity of what the sample constitutes1 BAG From where was the sample collectedSource
First name of sampler or witnessed byGERAEDO Last name of sampler or witnessed byZubieta
Title of samplerTE Civil Laboratory sample identification9060
The fabricator/manufacturer/facility nameHOLIDAY ROCK upland Transportation Laboratory (TL) NumberC923410
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)Unknown
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedunknown
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1 inch
The concrete mix design number3F36S002 Lot numberUnknown
Sublot numberUnknown HMA Design ID
Test Details
DIME Sample ID: 2019-12-18-25
DIME Test ID: 2019-12-18-25-1
Testing Lab: CT - Southern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2020-03-17
Test Results

What size aggregate is being tested?: 1 in. x No. 4 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Input Type: Calculated
Tester's full name: LARRY DIAZ
Date of test: 12/31/2019
Cumulative percent passing the 1 1/2 in. sieve:100 %
Cumulative percent passing the 1 in. sieve:100 %
Cumulative percent passing the 3/4 in. sieve:78 %
Cumulative percent passing the 1/2 in. sieve:17 %
Cumulative percent passing the 3/8 in. sieve:6 %
Cumulative percent passing the #4 sieve:4 %
Cumulative percent passing the #8 sieve:3.2 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 03/17/2020