Test 2020-01-16-2-2 (ASTM F606-14a) Summary

Project Information
Project IdentifiersProject ID: 3825
DEA: 07138204
EFIS: 0700000142
DIST-CO-RTE-PM07-LA-47,103-3.5/4.6,0.0/1.1
Work DescriptionREPLACE STEEL BRIDGE WITH CIP PS CONCRETE BOX GIRDER BRIDGE AND RAMPS.
Location DescriptionLOS ANGELES COUNTY IN LONG BEACH AND LOS ANGELES ON ROUTE 47 FROM OCEAN BOULEVARD TO ROUTE 103 JUNCTION AND ON ROUTE 103 FROM ROUTE 47 JUNCTION TO ANAHEIM STREET OVERHEAD
Sample Information
Sample Taken Date1/16/2020 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing1/20/2020
Sample typeQuality Assurance A brief description of the sample1 1/4"-7 x 10 3/4" HDG fastener assemblies
The quantity of what the sample constitutes13 From where was the sample collectedManufacturer
First name of sampler or witnessed bySteve Last name of sampler or witnessed byHall
Title of samplerCT METS QA INSPECTOR Laboratory sample identification
The fabricator/manufacturer/facility nameSt Louis Screw and Bolt Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL134-016-20 Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)Bolt 75063072 Nut 190424 Washer 9400873 Nut Mfg. Lot Number(s)30932
Washer Mfg. Lot Number(s)D7986 Bolt SpecificationASTM A325
Bolt Length(s)10 3/4" Nut SpecificationASTM A563 DH
Washer SpecificationF436 FinishHDG
Diameter/Size1 1/4" Bolt Mfg. Lot NumberJ36363
Rocap Test Requirement(s) Lubricant Requirements(s)
Test Details
DIME Sample ID: 2020-01-16-2
DIME Test ID: 2020-01-16-2-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2020-01-23
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 01/22/2020
UTM:450kip
Temperature:72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11A30932-190424146290Nut Proof Loadspaine

General comments (publicly viewable) (Max 250 characters): Nut Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 01/23/2020