Test 2019-09-04-11-1 (CTM 202-November 2011) Summary

Project Information
Project IdentifiersProject ID: 211260
DEA: 072159U4
EFIS: 0715000160
DIST-CO-RTE-PM07-LA,ORA-5-0.0/1.5, 44.3/44.4
Work DescriptionCONSTRUCT HOV LANES AND MIX FLOW LANES.
Location DescriptionLOS ANGELES AND ORANGE COUNTIES IN BUENA PARK, LA MIRADA, CERRITOS AND SANTA FE SPRINGS FROM ARTESIA BOULEVARD UNDERCROSSING TO NORTH FORK COYOTE CREEK
Sample Information
Sample Taken Date9/4/2019 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing9/5/2019
Sample typeQuality Control A brief description of the sampleRock and Sand
The quantity of what the sample constitutes1 Bag From where was the sample collectedSource
First name of sampler or witnessed byJulian Last name of sampler or witnessed byCarmona
Title of samplerQC Field Technician Laboratory sample identificationMix S75099
The fabricator/manufacturer/facility nameNational Ready Mix Artesia Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifier00-0000
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-19-0027
The fabricator's/manufacturer's product name for the sampleSet 1 The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedUnknown
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberS75099 Lot numberUnknown
Sublot numberUnknown HMA Design ID
Test Details
DIME Sample ID: 2019-09-04-11
DIME Test ID: 2019-09-04-11-1
Testing Lab: G3 Quality, Inc. - Cerritos
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2019-10-18
Test Results

What size aggregate is being tested?: 1 in. x No. 4 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Input Type: Calculated
Tester's full name: Ronald Hernandez
Date of test: 09/05/2019
Cumulative percent passing the 1 1/2 in. sieve:100 %
Cumulative percent passing the 1 in. sieve:99 %
Cumulative percent passing the 3/4 in. sieve:93 %
Cumulative percent passing the 1/2 in. sieve:63 %
Cumulative percent passing the 3/8 in. sieve:32 %
Cumulative percent passing the #4 sieve:6 %
Cumulative percent passing the #8 sieve:3 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/18/2019