Test 2019-09-12-7-4 (AASHTO T84-14) Summary

Project Information
Project IdentifiersProject ID: 209695
DEA: 08347704
EFIS: 0800000616
DIST-CO-RTE-PM08-SBD-SR-58-0/12.9
Work Description(Alternative Delivery) The CMGC project will upgrade SR 58 from 2- to 4-lanes in San Bernardino County from the Kern County line to 7.5 miles east of US-395.
Location DescriptionSR-58 / 395 Kramer Junction project. In San Bernardino County from the Kern County line to 7.5 miles east of US-395.
Sample Information
Sample Taken Date9/12/2019 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing9/16/2019
Sample typeVerification A brief description of the sample3/4 HMA-A-SP R15
The quantity of what the sample constitutesPSUE 17 Bags From where was the sample collectedManufacturer
First name of sampler or witnessed byVulcan Oro Grande Last name of sampler or witnessed byQC
Title of sampler Laboratory sample identification0531A-19
The fabricator/manufacturer/facility nameVMC Calmat San Bernardino, Hi Grade Lucerne Valley Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-36-0137, 91-36-0042
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R15 The fabricator/manufacturer designation for the sample224113 ORO SJR
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut at Vulcan Oro Grande Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown JMF Verification ID
Test Details
DIME Sample ID: 2019-09-12-7
DIME Test ID: 2019-09-12-7-4
Testing Lab: CT - Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2019-10-07
Test Results

Input Type: Measured
Tester's full name: Nader Rashidi
Date of test: 09/19/2019
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 969.6 grams
Mass of the pycnometer with water (B): 653 grams
Mass of the oven dried sample (before pycnometer) (A): 494.5 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 494.5 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity:2.696
Bulk specific gravity (SSD Basis):2.726
Apparent specific gravity:2.780
Absorption:1.1 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/07/2019