Summary for Test 2019-08-22-3-1
Test performed: ASTM F606-14Project Information
Project Identifiers | Project ID: 213600 DEA: 060T3014 EFIS: 0616000183 |
---|---|
DIST-CO-RTE-PM | 06-KER-14-16.6/16.6 |
Award Date | 11/09/2018 |
Closeout Date | 11/17/2021 |
Work Description | CONSTRUCT CREW BUILDING EQUIPMENT BUILDING AND RINSE FACILITY. |
Location Description | KERN COUNTY AT MOJAVE AT THE MOJAVE HIGHWAY MAINTENANCE STATION AT 2211 NADEAU STREET |
QA Service Level | 1 (Verified on 12/07/2018) |
Sample Information
Sample Taken Date | 08/22/2019 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/23/2019 |
Sample type | Quality Assurance | A brief description of the sample | 3/4" x 33" & 3/4" x 43" ASTM F1554 Gr 36 |
The quantity of what the sample constitutes | 1 each | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Ryan | Last name of sampler or witnessed by | Cummings |
Title of sampler | Associate Steel Inspector | Telephone number of sampler | 2096623492 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Portland Bolt Manufacturing | Transportation Laboratory (TL) Number | TL-101 - C600000 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S29-109-19 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 3088554 | Nut Mfg. Lot Number(s) | 30380-S-189067 |
Washer Mfg. Lot Number(s) | 0319-116 | Bolt Specification | F1554 |
Bolt Length(s) | 33" and 43" 1 of each | Nut Specification | A563 |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | 3/4 | Bolt Mfg. Lot Number | CMC Steel Texas |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2019-08-22-3
DIME Test ID: 2019-08-22-3-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2019-09-04
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 09/04/2019
UTM: 400kip
Temperature: 72
Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
---|---|---|---|---|---|---|---|---|---|
1 | 1 | UNC 3/4 | 0.334 | 26152 | 26151 | 78070 | 55725 | 18612 | F1554 Grade 36 Bar |
General comments (publicly viewable) (Max 1000 characters): F1554 Grade 36 Bar
Test Graph
Source: Bluehill Data Point FileTest was verified on 9/4/2019 ✔