Test 2019-06-25-1-2 (ASTM F606-14a) Summary

Project Information
Project IdentifiersProject ID: 3807
DEA: 07121844
EFIS: 0700000117
DIST-CO-RTE-PM07-LA-5-42.8/47.3
Work DescriptionCONSTRUCT HOV LANES, RETAINING WALLS AND SOUND WALLS.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES, GLENDALE, AND BURBANK FROM ROUTE 5/134 SEPARATION TO MAGNOLIA BOULEVARD OVERCROSSING
Sample Information
Sample Taken Date6/25/2019 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing6/28/2019
Sample typeQuality Assurance A brief description of the sampleA325 HDG Rocap Assembiy
The quantity of what the sample constitutes440 From where was the sample collectedDistributor
First name of sampler or witnessed byKevin Last name of sampler or witnessed byChurchill
Title of samplerQAI Laboratory sample identification
The fabricator/manufacturer/facility nameIndustrial Bolt and Supply Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL02-051-19 Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)00737
Heat Number(s)KH280 Nut Mfg. Lot Number(s)147527A
Washer Mfg. Lot Number(s)312019 Bolt SpecificationA325
Bolt Length(s)3.5" Nut SpecificationA194-2H
Washer SpecificationF436 FinishHot Dip Galvanized
Diameter/Size7/8" Bolt Mfg. Lot NumberB1910316G1
Rocap Test Requirement(s)Yes Lubricant Requirements(s)Yes
Test Details
DIME Sample ID: 2019-06-25-1
DIME Test ID: 2019-06-25-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2019-07-03
Test Results

Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Steve
Date of test: 07/02/2019
UTM:400KIP
Temperature:no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11BB1910316G17/8\"66345295.110A325Steve

General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point File

Test was verified on 07/03/2019