Test 2019-06-24-2-1 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 214223
DEA: 030J3104
EFIS: 0319000261
DIST-CO-RTE-PM03---
Work DescriptionNot set
Location DescriptionNot set
Sample Information
Sample Taken Date6/24/2019 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing6/25/2019
Sample typeQuality Assurance A brief description of the sample Couplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byAnthony Last name of sampler or witnessed byThurman
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameHarris Rebar Transportation Laboratory (TL) NumberC593830
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler Manufacturer Dayton Superior Intermediate Assembler or FabricatorUnknown
Rebar Size11 Coupler ModelBarLock
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)MM17105959 Rebar Heat Number(s)3500005321
Rebar Size 2
Test Details
DIME Sample ID: 2019-06-24-2
DIME Test ID: 2019-06-24-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2019-06-27
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 06/26/2019
UTM: 400KIP
Halo ID: Large
Temperature:72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11C03#11/36mm1.56-0.003514622093730Service SpliceBrian

General comments (publicly viewable) (Max 250 characters): Service Splice
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 06/27/2019