Summary for Test 2019-06-17-2-2
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 214223 DEA: 030J3104 EFIS: 0319000261 |
---|---|
DIST-CO-RTE-PM | 03-YUB-70-R9.28 |
Award Date | 05/17/2019 |
Closeout Date | 04/13/2021 |
Work Description | Not set |
Location Description | Not set |
QA Service Level | 1 (Verified on 06/18/2019) |
Sample Information
Sample Taken Date | 06/17/2019 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/18/2019 |
Sample type | Quality Assurance | A brief description of the sample | Dayton Bar lock couplers |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Anthony | Last name of sampler or witnessed by | Thurman |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Nucor Dayton Superior | Transportation Laboratory (TL) Number | C593829 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Service | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | Nucor |
Coupler Manufacturer | Dayton Superior | Intermediate Assembler or Fabricator | Unknown |
Rebar Size | 5 | Coupler Model | Bar-Lock Standard Couplers |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
Coupler Component Heat/Lot Number(s) | A150815 | Rebar Heat Number(s) | 3500004499 |
Rebar Size 2 | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2019-06-17-2
DIME Test ID: 2019-06-17-2-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2019-06-18
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 06/18/2019
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 2 | 1 | #5/16mm | 0.31 | 0 | 29026 | 93632 | Service Splice | Fred |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 6/18/2019 ✔