Test 2019-05-24-5-10 (CTM 202-November 2011) Summary

Project Information
Project IdentifiersProject ID: 213603
DEA: 07301504
EFIS: 0714000020
DIST-CO-RTE-PM07-LA-1,10-R34.6/35.2,R2.1/18.4
Work DescriptionREPLACING CONCRETE AND AC PAVEMENT
Location DescriptionLOS ANGELES COUNTY IN SANTA MONICA AND LOS ANGELES ON ROUTE 1 FROM 0.1 MILE WEST OF MAIN STREET OVERCROSSING TO ROUTE 1/10 SEPARATION AND ON ROUTE 10 FROM ROUTE 1/10 SEPARATION TO ROUTE 5/10 SEPARATION AND AT ROUTE 10/110 SEPARATION
Sample Information
Sample Taken Date5/24/2019 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing5/29/2019
Sample typeVerification A brief description of the sample1/2 HMA-A-SP R15
The quantity of what the sample constitutesJMF 7 bags From where was the sample collectedManufacturer
First name of sampler or witnessed byVulcan Irwindale Last name of sampler or witnessed byQC
Title of sampler Laboratory sample identification0307A-19
The fabricator/manufacturer/facility nameVulcan Irwindale Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)Vulcan Irwindale
The fabricator's/manufacturer's product name for the sample1/2 HMA-A-SP R15 The fabricator/manufacturer designation for the sample320819 IRW LTR
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut at Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown JMF Verification ID
Test Details
DIME Sample ID: 2019-05-24-5
DIME Test ID: 2019-05-24-5-10
Testing Lab: CT - Southern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2019-07-03
Test Results

What size aggregate is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Input Type: Calculated
Tester's full name: Michael Magana
Date of test: 06/13/2019
Cumulative percent passing the 3 in. sieve:100 %
Cumulative percent passing the 2 1/2 in. sieve:100 %
Cumulative percent passing the 2 in. sieve:100 %
Cumulative percent passing the 1 1/2 in. sieve:100 %
Cumulative percent passing the 1 in. sieve:100 %
Cumulative percent passing the 3/4 in. sieve:100 %
Cumulative percent passing the 1/2 in. sieve:97 %
Cumulative percent passing the 3/8 in. sieve:88 %
Cumulative percent passing the #4 sieve:58 %
Cumulative percent passing the #8 sieve:40 %
Cumulative percent passing the #16 sieve:28 %
Cumulative percent passing the #30 sieve:20 %
Cumulative percent passing the #50 sieve:12 %
Cumulative percent passing the #100 sieve:7 %
Cumulative percent passing the #200 sieve:4 %
General comments (publicly viewable) (Max 1000 characters): Combined Virgin Aggregate/RAP Gradation w/Correlation Factors Applied

Test was verified on 07/03/2019