Summary for Test 2019-04-28-1-5
Test performed: AASHTO T324-14Project Information
Project Identifiers | Project ID: 213912 DEA: 033H71U4 EFIS: 0319000051 |
---|---|
DIST-CO-RTE-PM | 03-BUT-70-8.8/12.1 |
Award Date | 05/09/2019 |
Closeout Date | 09/23/2021 |
Work Description | WIDEN RDWY, RDWY EX, HMA & MODIFY ELECT SYSTEM. |
Location Description | BUTTE COUNTY NEAR OROVILLE FROM 0.1 MILE SOUTH OF PALERMO ROAD TO 0.6 MILE NORTH OF OPHIR ROAD |
QA Service Level | 1 (Verified on 02/21/2019) |
Sample Information
Sample Taken Date | 04/28/2019 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/19/2019 |
Sample type | Quality Control | A brief description of the sample | JMF mix design data |
The quantity of what the sample constitutes | 1 production lot | From where was the sample collected | Source |
First name of sampler or witnessed by | Jon | Last name of sampler or witnessed by | Blumer |
Title of sampler | Telephone number of sampler | 916-386-6985 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Teichert Materials Hallwood | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | Unknown |
Sublot number | Unknown | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2019-04-28-1
DIME Test ID: 2019-04-28-1-5
Testing Lab: Teichert Materials - Sacramento
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Test Release Date: 2019-05-29
Test Results
Input Type: Calculated
Tester's full name: Eric Gifford
Date of test: 04/19/2019
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth average: no data
Impression at specified number of passes average: no data
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A): 25000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B): 25000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A): 6.23 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B): 4.64 mm
Stripping Inflection Point (Wheel A): 25000
Stripping Inflection Point (Wheel B): 25000
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/29/2019 ✔