Test 2018-07-14-7-1 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 212731
DEA: 07318004
EFIS: 0715000280
DIST-CO-RTE-PM07-LA-10-22.3/28.2
Work DescriptionTREAT BRIDGE DECK, CLOSURE POUR AND REPLACE JOINT SEALS.
Location DescriptionLOS ANGELES COUNTY AT VARIOUS LOCATIONS FROM FREMONT AVENUE UNDERCROSSING TO RIO HONDO62
Sample Information
Sample Taken Date7/14/2018 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing8/6/2018
Sample typeQuality Assurance A brief description of the sampleCouplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byRuben Last name of sampler or witnessed bySanduval
Title of samplerUnknown Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameGerdau BarSplice Transportation Laboratory (TL) NumberC672056
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar Manufacturer Gerdau
Coupler ManufacturerBarSplice Intermediate Assembler or FabricatorUnknown
Rebar Size5 Coupler ModelDBL BRL Zap Screwlok
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)80172 Rebar Heat Number(s) 65031313
Rebar Size 2
Test Details
DIME Sample ID: 2018-07-14-7
DIME Test ID: 2018-07-14-7-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2018-08-16
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 08/09/2018
UTM:400KIP
Temperature:72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
121#5/16mm0.312823091060Service SpliceBrian

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 08/09/2018