Test 2018-04-06-7-1 (ASTM C39-10) Summary

Project Information
Project IdentifiersProject ID: 208945
DEA: 07288604
EFIS: 0700021080
COOP: 074663
DIST-CO-RTE-PM07-LA-710-6.0-9.4
Work DescriptionGerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location DescriptionPort of Long Beach (District 7)
Sample Information
Sample Taken Date4/6/2018 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing4/10/2018
Sample typeQuality Assurance A brief description of the sample6X12
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byGARY Last name of sampler or witnessed byMaCOMB
Title of samplerASSOC STEEL INSP Laboratory sample identification866-3918
The fabricator/manufacturer/facility nameA AND A Transportation Laboratory (TL) NumberL10-039-18
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierPRECAST BRIDGE DECKSLABS LIGHTWEIGHT DECK SLAB A11 217
Structure namePRECAST BRIDGE DECKSLABS LIGHTWEIGHT DECK SLAB A11 217
Material Information
Material TypeConcrete The concrete mix design numberSFI-LWSBS5
The truck number from where the sample was collected374 The batch plant ticket number from where the sample was collected426046
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedCHUTE Where the material sample would have been placed if not sampledPRECAST BRIDGE DECKSLABS LIGHTWEIGHT DECK SLAB A11 217
From Lot No.Unknown Bag Lot No.Unknown
Test Details
DIME Sample ID: 2018-04-06-7
DIME Test ID: 2018-04-06-7-1
Testing Lab: CT - Southern Regional Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2018-08-06
Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: MM
Date of test: 07/27/2018
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.02 in
Average diameter of cylinder 2: 6.02 in
Maximum load on cylinder 1: 179940 lb
Maximum load on cylinder 2: 176240 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 112 days
Cross sectional area of cylinder 1: 28.46 in^2
Cross sectional area of cylinder 2: 28.46 in^2
Compressive strength of cylinder 1: 6322.6 psi
Compressive strength of cylinder 2: 6192.6 psi
Compressive strength (to nearest 10 psi):6260 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 07/30/2018