Summary for Test 2018-07-10-8-1
Test performed: ASTM A370-15Project Information
Project Identifiers | Project ID: 213491 DEA: 031H6104 EFIS: 0316000190 |
---|---|
DIST-CO-RTE-PM | 03--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | METS is performing preliminary field investigation and testing to help design choose a retrofitting plan for the Sacramento West End Viaduct. |
Location Description | Not set |
QA Service Level | 1 (Verified on 11/22/2019) |
Sample Information
Sample Taken Date | 07/10/2018 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/20/2018 |
Sample type | Quality Assurance | A brief description of the sample | Check Sample Plates |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Joshua | Last name of sampler or witnessed by | Moore |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Unknown | Transportation Laboratory (TL) Number | C740528 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM6 - Steel Check Sample Plate | Heat Number(s) | Unknown |
---|---|---|---|
Material Specification | A36 | Grade | Unknown |
Thickness | 0.3125 | Shape | Rectangle |
Metal Foundry Manufacturer (Mill) | Unkown | Plate Dimension | 8.250" x 3.250" |
Test Details
DIME Sample ID: 2018-07-10-8
DIME Test ID: 2018-07-10-8-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Flat Sample)
Test Release Date: 2018-08-01
Test Results
Number of Samples: 2
Input Type: Calculated
Tester's full name: Brian
Date of test: 07/25/2018
UTM: 67KIP
Temperature: 72 F
Num | Sample | Heat Number | Width (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Total Elongation (%) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | N/A | 0.501 | 0.1493 | 43117 | 65559 | 30.8 | Brian | |
2 | N/A | 0.506 | 0.1498 | 42481 | 66088 | 34.9 | Brian |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Test was verified on 7/25/2018 ✔