Test 2018-06-04-28-5 (ASTM E23-12c) Summary

Project Information
Project IdentifiersProject ID: 213406
DEA: 030F2504
EFIS: 0300000075
DIST-CO-RTE-PM03-YOL,SAC-80-R11.1/R11.7,M0.0/M0.5
Work DescriptionSAC RIVER BOH (BRYTE BEND)
Location DescriptionSACRAMENTO AND YOLO COUNTIES IN WEST SACRAMENTO AND SACRAMENTO FROM 0.1 MILE WEST OF REED AVENUE UNDERCROSSING TO 0.1 MILE EAST OF SACRAMENTO RIVER BRIDGE AND OVERHEAD
Sample Information
Sample Taken Date6/4/2018 Sample Unique Key28
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing6/6/2018
Sample typeVerification A brief description of the samplePlate samples cut from bridge.
The quantity of what the sample constitutes6 From where was the sample collectedSource
First name of sampler or witnessed byMike Last name of sampler or witnessed byMullins
Title of samplerUnknown Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameBryte Bend Bridge Transportation Laboratory (TL) NumberC704036
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM6 - Steel Check Sample Plate Heat Number(s)A, B, C, D, E, F
Material SpecificationA36 GradeA36, A441
Thickness.375 in .312 in ShapeRound
Metal Foundry Manufacturer (Mill)Unknown Plate Dimension3.625 in Round
Test Details
DIME Sample ID: 2018-06-04-28
DIME Test ID: 2018-06-04-28-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM E23-12c: Standard Test Methods for Notched Bar Impact Testing of Metallic Materials (Charpy Impact)
Test Release Date: 2018-06-26
Test Results

Input Type: Measured
Tester's full name: Glen Weldon
Date of test: 06/14/2018
Temperature Required: 70 oF
Minimum Energy Required: 7 ftlb
Test Temperature 1: 69 oF
Impact Energy 1: 43 ftlb
Impact Energy 2: 52 ftlb
Impact Energy 3: 53 ftlb
Striker Radius: 8
Average Impact Energy:49 ftlb
Value Exceeds The Machine Capacity?:No
General comments (publicly viewable) (Max 1000 characters): Test sample C

Test was verified on 06/19/2018