Test 2018-06-11-8-4 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 212706
DEA: 051J4004
EFIS: 0517000095
DIST-CO-RTE-PM05-SCR-9-11.0
Work DescriptionRepair Slipout damage by constructing sidehill viaduct
Location DescriptionNot set
Sample Information
Sample Taken Date6/11/2018 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing6/15/2018
Sample typeQuality Assurance A brief description of the sample Couplers
The quantity of what the sample constitutes8 From where was the sample collectedJob Site
First name of sampler or witnessed byK Last name of sampler or witnessed byNowak
Title of samplerUnknown Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameDextra America Nucor Transportation Laboratory (TL) NumberNA
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerDextra America Intermediate Assembler or FabricatorUnknown
Rebar Size8, 9 Coupler ModelNA
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)4329,3801, 3715 Rebar Heat Number(s)Pl17110058, SE17101154
Rebar Size 2 Not set
Test Details
DIME Sample ID: 2018-06-11-8
DIME Test ID: 2018-06-11-8-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2018-06-25
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 06/18/2018
UTM: 400KIP
Halo ID: Small
Temperature:72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
111#9/29mm1-0.00099096690966Ok NeckingBrian

General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 06/18/2018