Summary for Test 2018-05-17-9-1

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 209695
DEA: 08347704
EFIS: 0800000616
DIST-CO-RTE-PM08-SBD-SR-58-0/12.9
Award Date11/10/2017
Closeout Date01/14/2021
Work Description(Alternative Delivery) The CMGC project will upgrade SR 58 from 2- to 4-lanes in San Bernardino County from the Kern County line to 7.5 miles east of US-395.
Location DescriptionSR-58 / 395 Kramer Junction project. In San Bernardino County from the Kern County line to 7.5 miles east of US-395.
QA Service Level1 (Verified on 12/01/2017)

Sample Information

Sample Taken Date05/17/2018 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/21/2018
Sample typeQuality Assurance A brief description of the sampleprecast box culvert number 3
The quantity of what the sample constitutes2 From where was the sample collectedJob Site
First name of sampler or witnessed byOSAMA Last name of sampler or witnessed byABDALLA
Title of samplerASI Telephone number of samplerUnknown
Laboratory sample identification976-4118 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameVulcan San Bernardino Transportation Laboratory (TL) Number976-4118
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierBOX CULVER NUMBER 3
Structure name10X5 SINGLE CELL BOX CULVER NUMBER 3

Material Information

Material TypeConcrete The concrete mix design numberUV315
The truck number from where the sample was collectedUnknown The batch plant ticket number from where the sample was collected993614
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleKIEWIT INFRANSTRUCTUREWEST
A detailed description of where the material sample was collectedAUGER DIS Where the material sample would have been placed if not sampled10X5 SINGLE CELL BOX CULVER NUMBER 3
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2018-05-17-9
DIME Test ID: 2018-05-17-9-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2018-06-01

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Minh Pham
Date of test: 05/24/2018
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 182140 lb
Maximum load on cylinder 2: 182520 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 7 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 6442.9 psi
Compressive strength of cylinder 2: 6456.3 psi
Compressive strength (to nearest 10 psi): 6450 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/25/2018