Test 2018-03-13-10-2 (ASTM D412-06a-re13) Summary

Project Information
Project IdentifiersProject ID: 210569
DEA: 083555V4
EFIS: 0814000086
DIST-CO-RTE-PM08-SBD-15-42.5/46.0
Work DescriptionWIDEN I-15, RECONSTRUCT 3 IC'S, CONSTRUCT 2 NEW BR AND WIDEN 3 BR.
Location DescriptionSAN BERNARDINO COUNTY IN VICTORVILLE FROM 0.5 MILE NORTH OF MOJAVE DRIVE TO 1.5 MILE NORTH OF STODDARD WELLS ROAD OVERCROSSING
Sample Information
Sample Taken Date3/13/2018 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing3/15/2018
Sample typeQuality Assurance A brief description of the sampleBearing Pad
The quantity of what the sample constitutes1 From where was the sample collectedManufacturer
First name of sampler or witnessed byPet Last name of sampler or witnessed byEtcheverry
Title of samplerUnknown Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameScougal Rubber Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM1 - Elastomeric Bearing Pad Mfg. Lot Number(s)16318-1R
Material/Compound/Elastomer IDUnknown Samples Representing11
Description (size)5"x15"x15" CommentsUnknown
Description (Number of Shims)10 Type of Bearing PadSteel
Description (Thickness of Shims)14 gage Manufacturer(s)Scougal Rubber
Batch NumberUnknown
Test Details
DIME Sample ID: 2018-03-13-10
DIME Test ID: 2018-03-13-10-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers—Tension
Test Release Date: 2018-04-02
Test Results

Input Type: Calculated
Tester's full name: Randy
Date of test: 03/19/2018
UTM: 2KIP
Humidity: 50 %
Temperature: 72 F
Sample 1 Median Thickness:0.067 in
Sample 1 Thickness all Within 0.003 inch?:Yes
Sample 1 Ultimate Tensile:2202.4 lbf/in^2
Sample 1 Elongation (350% Min):Pass
Sample 2 Median Thickness:0.07 in
Sample 2 Thickness all Within 0.003 inch?:Yes
Sample 2 Ultimate Tensile:2342.9 lbf/in^2
Sample 2 Elongation (350% Min):Pass
Sample 3 Median Thickness:0.068 in
Sample 3 Thickness all Within 0.003 inch?:Yes
Sample 3 Ultimate Tensile:2058.8 lbf/in^2
Sample 3 Elongation (350% Min):Pass
Sample 4 Median Thickness:0.065 in
Sample 4 Thickness all Within 0.003 inch?:Yes
Sample 4 Ultimate Tensile:2454 lbf/in^2
Sample 4 Elongation (350% Min):Pass
Sample 5 Median Thickness:0.067 in
Sample 5 Thickness all Within 0.003 inch?:Yes
Sample 5 Ultimate Tensile:2381 lbf/in^2
Sample 5 Elongation (350% Min):Pass
Median of the Ultimate Tensile Values:2342.9 lbf/in^2
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point File
Test graph for Sample 1

Source: Partner Data Point File
Test graph for Sample 2

Source: Partner Data Point File
Test graph for Sample 3

Source: Partner Data Point File
Test graph for Sample 4

Source: Partner Data Point File
Test graph for Sample 5

Test was verified on 03/26/2018