Summary for Test 2017-12-27-1-4
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 209146 DEA: 06471504 EFIS: 0600000464 COOP: 061549 |
---|---|
DIST-CO-RTE-PM | 06-TUL-99-39.6/41.3 |
Award Date | 02/24/2017 |
Closeout Date | 03/03/2020 |
Work Description | RECONSTRUCT INTERCHANGE WITH NEW PUMPING PLANT. |
Location Description | TULARE COUNTY AT GOSHEN FROM 0.9 MILE NORTH OF ROUTE 99/198 WEST SEPARATION TO 0.2 MILE NORTH OF NORTH GOSHEN OVERHEAD |
QA Service Level | 1 (Verified on 10/08/2013) |
Sample Information
Sample Taken Date | 12/27/2017 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/04/2018 |
Sample type | Quality Assurance | A brief description of the sample | HRC 500 510 Couplers |
The quantity of what the sample constitutes | 12 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Justin | Last name of sampler or witnessed by | Palmaymesa |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | CMC HRC | Transportation Laboratory (TL) Number | 982926 982927 982930 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Service | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | CMC Rebar |
Coupler Manufacturer | HRC | Intermediate Assembler or Fabricator | Unknown |
Rebar Size | #8,10 | Coupler Model | HRC 500-510 |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
Coupler Component Heat/Lot Number(s) | 177275, 177488, A162884 | Rebar Heat Number(s) | 4069024, 4070783 |
Rebar Size 2 | Not set | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2017-12-27-1
DIME Test ID: 2017-12-27-1-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2018-01-12
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 01/05/2018
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 1 | 2 | #8/25mm | 0.79 | -0.0111 | 72098 | 91263 | OK Necking | Fred |
General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 1/5/2018 ✔