Test 2014-01-28-9155223-5 (ASTM C39-10) Summary

Project Information
Project IdentifiersProject ID: 10016
DEA: 06342524
EFIS: 0600000381
DIST-CO-RTE-PM06-FRE-180-R71.8/74.5
Work DescriptionNEW EXPRESS HIGHWAY
Location DescriptionFRESNO COUNTY ABOUT 6.3 MILES EAST OF FRESNO FROM 0.6 MILE WEST OF QUALITY AVENUE TO 0.2 MILE WEST OF SMITH AVENUE
Sample Information
Sample Taken Date1/28/2014 Sample Unique Key9155223
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing1/29/2014
Sample typeQuality Control A brief description of the sampleType II Cement
The quantity of what the sample constitutes8 concrete cylinders From where was the sample collectedOther
First name of sampler or witnessed byJoshua Last name of sampler or witnessed byGuilmette
Title of samplerQC Field Technician/Inspector Laboratory sample identification2014-01-28-09-15
The fabricator/manufacturer/facility nameW/B Hwy 180 at Lone Treen Canal approach ramp Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierLone Tree Canal approach ramp
Structure nameLone Tree Canal approach ramp
Material Information
Material TypeConcrete The concrete mix design numberND22023
The truck number from where the sample was collected9379 The batch plant ticket number from where the sample was collected114103654
Concrete batch plant114 The fabricator/manufacturer designation for the samplePlant
A detailed description of where the material sample was collectedLone Tree Canal approach ramp Where the material sample would have been placed if not sampledLone Tree Canal approach ramp
From Lot No.Not set Bag Lot No.Not set
Test Details
DIME Sample ID: 2014-01-28-9155223
DIME Test ID: 2014-01-28-9155223-5
Testing Lab: Trinity Engineering Laboratories, Inc. - Fresno
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2014-03-21
Test Results

Unit system used?: US Units
Number of specimens: 1
Test performed: With density determined by dimension measurements
Input Type: Calculated
Tester's full name: Joshua Guilmette
Date of test: 02/11/2014
Average diameter of cylinder 1: 6.00 in
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Density of cylinder:146.8 lb/ft^3
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 03/21/2014