Test 2017-10-01-1-1 (AGGLP SIEVE_ANALYSIS-1) Summary

Project Information
Project IdentifiersProject ID: 212838
DEA: 044K4404
EFIS: 0417000310
MINOR: 04A5388
DIST-CO-RTE-PM04-CC-4-40.38-41.05
Work DescriptionInstall two Solar Powered Vehical Speed Feedback Signs (VSFS)
Location DescriptionIn Contra Costa County on Route 004 at PM 40.38 and PM 41.05.
Sample Information
Sample Taken Date10/1/2017 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/24/2017
Sample typeQuality Control A brief description of the sampleFoundation
The quantity of what the sample constitutes1 bag From where was the sample collectedJob Site
First name of sampler or witnessed bySamuel Last name of sampler or witnessed byAwad
Title of samplerUnknown Laboratory sample identification17SOIL-0311
The fabricator/manufacturer/facility nameNA Transportation Laboratory (TL) NumberC002129
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSoil The fabricator's/manufacturer's product name for the sampleUnknown
The fabricator/manufacturer designation for the sampleUnknown A detailed description of where the material sample was collectedA-17-001
Where the material sample would have been placed if not sampled5 to 10 ft
Test Details
DIME Sample ID: 2017-10-01-1
DIME Test ID: 2017-10-01-1-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AGGLP SIEVE_ANALYSIS-1: Soils for Corrosion Sieve Analysis
Test Release Date: 2017-11-01
Test Results

Input Type: Measured
Tester's full name: Phillip Montes
Date of test: 11/01/2017
Total mass of material in the sample: 3391 grams
Cumulative mass retained on the 2 in. sieve: 0 grams
Cumulative mass retained on the 1 1/2 in. sieve: 0 grams
Cumulative mass retained on the 1 in. sieve: 0 grams
Cumulative mass retained on the 3/4 in. sieve: 0 grams
Cumulative mass retained on the 1/2 in. sieve: 5 grams
Cumulative mass retained on the 3/8 in. sieve: 3 grams
Cumulative mass retained on the #4 sieve: 22 grams
Cumulative mass retained on the #8 sieve: 31 grams
Total sample mass passing the #4 sieve: 1610 grams
Total mass of fine material in the sample: 814 grams
Mass retained on the pan (fine aggregate): 782 grams
Total cumulative mass of coarse aggregate: 30 grams
Total cumulative mass of fine aggregate: 813 grams
Sum of coarse and fine aggregate: 1640
Percentage of coarse material: 2 %
Percentage of fine material: 98 %
Cumulative percent passing the 2 in. sieve:100 %
Cumulative percent passing the 1 1/2 in. sieve:100 %
Cumulative percent passing the 1 in. sieve:100 %
Cumulative percent passing the 3/4 in. sieve:100 %
Cumulative percent passing the 1/2 in. sieve:100 %
Cumulative percent passing the 3/8 in. sieve:100 %
Cumulative percent passing the #4 sieve:98 %
Cumulative percent passing the #8 sieve:94 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/01/2017