Test 2017-04-19-14-2 (CTM 202-November 2014) Summary

Project Information
Project IdentifiersProject ID: 211260
DEA: 072159U4
EFIS: 0715000160
DIST-CO-RTE-PM07-LA,ORA-5-0.0/1.5, 44.3/44.4
Work DescriptionCONSTRUCT HOV LANES AND MIX FLOW LANES.
Location DescriptionLOS ANGELES AND ORANGE COUNTIES IN BUENA PARK, LA MIRADA, CERRITOS AND SANTA FE SPRINGS FROM ARTESIA BOULEVARD UNDERCROSSING TO NORTH FORK COYOTE CREEK
Sample Information
Sample Taken Date4/19/2017 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing4/20/2017
Sample typeQuality Control A brief description of the sampleRock and Sand
The quantity of what the sample constitutes1 Bag From where was the sample collectedSource
First name of sampler or witnessed byRyan Last name of sampler or witnessed byDeVaul
Title of samplerQC Field Technician Laboratory sample identificationMix HRC14058
The fabricator/manufacturer/facility nameHolliday Rock Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-19-0025::IRWINDALE
The fabricator's/manufacturer's product name for the sampleSet 1 The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedUnknown
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1 inch
The concrete mix design numberHRC14058 Lot numberNot set
Sublot numberNot set HMA Design ID
Test Details
DIME Sample ID: 2017-04-19-14
DIME Test ID: 2017-04-19-14-2
Testing Lab: G3 Quality, Inc. - Cerritos
Test Method: CTM 202-November 2014: Method of Test for Determining Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2017-07-21
Test Results

What size aggregate is being tested?: Fine Aggregate
Input Type: Calculated
Tester's full name: Devin Feurtey
Date of test: 04/20/2017
Cumulative percent passing the 3/8 in. sieve:100 %
Cumulative percent passing the #4 sieve:98 %
Cumulative percent passing the #8 sieve:82 %
Cumulative percent passing the #16 sieve:63 %
Cumulative percent passing the #30 sieve:40 %
Cumulative percent passing the #50 sieve:19 %
Cumulative percent passing the #100 sieve:6 %
Cumulative percent passing the #200 sieve:3 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 07/21/2017