Test 2017-05-19-4-4 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 211513
DEA: 120M4904
EFIS: 1212000090
DIST-CO-RTE-PM12-ORA-5-1.2/2.2
Work DescriptionWIDEN FWY AND BRIDGE AND CONSTRUCT RW, SOUND WALL, AND CONC BARRIERS.
Location DescriptionORANGE COUNTY IN SAN CLEMENTE FROM 0.1 MILE NORTH OF AVENIDA MENDOCINO OVERCROSSING TO 0.2 MILE SOUTH OF AVENIDA PRESIDIO UNDERCROSSING
Sample Information
Sample Taken Date5/19/2017 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing5/22/2017
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes8 From where was the sample collectedFabricator
First name of sampler or witnessed byDavid Last name of sampler or witnessed byGray
Title of samplerUnknown Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameTNT Rebar Bayou Steel Transportation Laboratory (TL) NumberC943256
Inspector Lot Number from the Transportation Laboratory (TL) FormS3203817 Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)1710457
Hoop Manufacturer Lot Number(s)1, 2 Material Standard CodeASTM A706
Material Grade60 Rebar Size7
Diameter of Hoop3'-8" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerBayou Steel
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded
Test Details
DIME Sample ID: 2017-05-19-4
DIME Test ID: 2017-05-19-4-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2017-05-30
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 05/23/2017
UTM:400KIP
Temperature:72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
112#7/22mm0.65912098530Bar BrokeBrian

General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 05/23/2017