Summary for Test 2017-05-05-1-2

Test performed: ASTM A775-07b-re14

Project Information

Project IdentifiersProject ID: 211854
DEA: 043G0804
EFIS: 0400021272
DIST-CO-RTE-PM04-SON-1-30.5
Award Date01/20/2017
Closeout Date02/27/2019
Work DescriptionCONSTRUCT ROADWAY AND SOIL NAIL WALLS
Location DescriptionSONOMA COUNTY NEAR FORT ROSS AT 2.6 MILES SOUTH OF FORT ROSS ROAD
QA Service Level1 (Verified on 03/13/2017)

Sample Information

Sample Taken Date05/05/2017 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/09/2017
Sample typeQuality Assurance A brief description of the sampleEpoxy coated coupler, Grade 75
The quantity of what the sample constitutes2 From where was the sample collectedManufacturer
First name of sampler or witnessed byKen Last name of sampler or witnessed byVarela
Title of samplerAssociate Steel Inspector Telephone number of sampler(213) 620-2341
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameWilliams Form Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormL08-039-17 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A615
Material Grade60 Rebar Manufacturerunknown
Coupler ManufacturerWilliams Form Intermediate Assembler or FabricatorEaton Steel Bar Co
Rebar SizeNo. 8 Coupler Modelunknown
Coating StandardsASTM A934 Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)unknown Rebar Heat Number(s)unknown
Rebar Size 2 Not set Coupler Unique IDNot set

Test Details

DIME Sample ID: 2017-05-05-1
DIME Test ID: 2017-05-05-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)
Test Release Date: 2017-05-18

Test Results


Input Type: Measured
Tester's full name: Glen Weldon
Date of test: 05/10/2017
Lower spec. limit LSL: 10 mils
Upper spec. limit USL: 15 mils
Bar # for First Bar: no data
Bar # for Second Bar: no data
First Bar Side 1 mean value: 11.95 mils
First Bar Side 2 mean value: 10.13 mils
Second Bar Side 1 mean value: 8.646 mils
Second Bar Side 2 mean value: 7.338 mils
First Bar Mean: 11.04 mils
Second Bar Mean: 7.99 mils
Total mean value: 9.52 mils
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/11/2017