Summary for Test 2017-02-06-3-1

Test performed: CONCLP 3-16

Project Information

Project IdentifiersProject ID: 211593
DEA: 034F0904
DIST-CO-RTE-PM03-SAC-5,80-17.2,M8.9
Award Date09/20/2016
Closeout Date08/30/2018
Work DescriptionREHABILITATE BRIDGE DECKS
Location DescriptionSACRAMENTO COUNTY IN SACRAMENTO ON ROUTE 5 AT FLORIN ROAD OVERCROSSING AND ON ROUTE 80 AT DEL PASO PARK OVERHEAD
QA Service Level1 (Verified on 10/20/2016)

Sample Information

Sample Taken Date02/06/2017 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/08/2017
Sample typeQuality Assurance A brief description of the samplepolyester resin
The quantity of what the sample constitutes80000 From where was the sample collectedManufacturer
First name of sampler or witnessed byChris Last name of sampler or witnessed bynanes
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identification17-010 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility namereichhold azusa Transportation Laboratory (TL) Numberc594916
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypePolyester Mfg. Lot Number(s)1030651
Batch number1030651 Mix number3224

Test Details

DIME Sample ID: 2017-02-06-3
DIME Test ID: 2017-02-06-3-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 3-16: Polyester Resin
Test Release Date: 2017-05-25

Test Results


Input Type: Calculated
Tester's full name: Mike Mullins
Date of test: 02/13/2017
Viscosity ASTM D 2196, RVT, No. 1 spindle 75 to 200 cps @ 20 RPM, 77°F: 130 cps
Specific gravity ASTM D 1475 1.05 to 1.10 @ 77°F: 1.09
Conditioning (18/25/50 + 5/70) Elogation ASTM D 638, minimum 35%: 56.4 %
Tensile Strength ASTM D 638 Type 1 @ 0.45 in/min, minimum 2500 psi: 2939 psi
Styrene ASTM D 2369 40% to 50 %: 47 %
PCC - SSD bond strength CTM 551 500 psi minimun @ 24 hours: 619 psi
Static Volatile Emissions, SCAQMD 309-91, maximum loss 1.0 grams: 0.5 grams
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/25/2017