Test 2016-11-10-2-2 (ASTM C39-17a) Summary

Project Information
Project IdentifiersProject ID: 211393
DEA: 081F1104
EFIS: 0814000160
DIST-CO-RTE-PM08-SBD-38-38.6-L5759
Work DescriptionCONSTRUCT A SAND HOUSE AND CHAIN LINK FENCE AT ONYX SUMMIT
Location DescriptionSAN BERNARDINO COUNTY AT ONYX SUMMIT 0.7 MILES SOUTH OF PIPES ROAD
Sample Information
Sample Taken Date11/10/2016 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/14/2016
Sample typeQuality Control A brief description of the sample6x12
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byARNEL Last name of sampler or witnessed byVEGA
Title of samplerASR Laboratory sample identification949-02
The fabricator/manufacturer/facility nameROBERTSONS MIX Transportation Laboratory (TL) Number02
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierONYX SUMMIT SAND HOUSE
Structure nameSLAB
Material Information
Material TypeConcrete The concrete mix design numberRRM09013
The truck number from where the sample was collected1169 The batch plant ticket number from where the sample was collected2319290
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedTAIL GATE Where the material sample would have been placed if not sampledUnknown
From Lot No.Unknown Bag Lot No.Unknown
Test Details
DIME Sample ID: 2016-11-10-2
DIME Test ID: 2016-11-10-2-2
Testing Lab: CT - Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2017-01-10
Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 12/08/2016
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.98 in
Average diameter of cylinder 2: 5.98 in
Maximum load on cylinder 1: 172370 lb
Maximum load on cylinder 2: 172260 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.09 in^2
Cross sectional area of cylinder 2: 28.09 in^2
Compressive strength of cylinder 1: 6136.3 psi
Compressive strength of cylinder 2: 6132.4 psi
Compressive strength (to nearest 10 psi):6130 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 01/03/2017