Test 2016-07-21-14-2 (ASTM A615-15) Summary

Project Information
Project IdentifiersProject ID: 210770
DEA: 11408004
EFIS: 1100020480
DIST-CO-RTE-PM11-SD-79-0.0/29.6
Work DescriptionUPGRADE BRIDGE RAIL AND GUARDRAIL, AND SLOPE REPAIR.
Location DescriptionIN SAN DIEGO COUNTY AT VARIOUS LOCATIONS FROM 0.1 MILE SOUTH OFSAMAGATUMA CREEK BRIDGE TO 0.1 MILE NORTH OF MATAGUAL CREEK BRIDGE
Sample Information
Sample Taken Date7/21/2016 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing7/26/2016
Sample typeQuality Assurance A brief description of the sampleThreaded Rebar
The quantity of what the sample constitutes2 From where was the sample collectedDistributor
First name of sampler or witnessed byTory Last name of sampler or witnessed byMclaurin
Title of samplerUnknown Laboratory sample identificationBar 6214075905 Nut 000W18127
The fabricator/manufacturer/facility nameDSI Gerdau Transportation Laboratory (TL) NumberC731356
Inspector Lot Number from the Transportation Laboratory (TL) FormL6715116 Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingProduction Testing
Threaded Bar SpecificationASTM A615 Threaded Bar Grade75
Threaded Bar TypeDeformed Rebar Size8
Nut Specification for Threaded BarNA System ManufacturerDSI
Epoxy Coating ColorNA Threaded Bar ApplicationSoil Nail
Coating StandardsUncoated Bar Heat Number(s)
Nut Heat Number(s) Bar Lot Number
Nut Lot Number Coupler Heat Number(s)
Coupler Grade
Test Details
DIME Sample ID: 2016-07-21-14
DIME Test ID: 2016-07-21-14-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2016-08-01
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 07/28/2016
UTM: 400KIP
Temperature:72 F
NumSampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)CommentsTested By
12#8 Bar Heat #6214075950, Nut Heat #000W18127L67151160.79111227809026.1Nut Stripped Off Bar Did Not BreakFred

General comments (publicly viewable) (Max 1000 characters): Nut Stripped Off Bar Did Not Break
Test Graph
Source: Partner Data Point File

Test was verified on 08/01/2016