Test 2016-07-07-11-2 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 210277
DEA: 051F8904
EFIS: 0514000072
DIST-CO-RTE-PM05-MON-1-28.0/28.4
Work DescriptionCONSTRUCT VIADUCT.
Location DescriptionMONTEREY COUNTY NEAR LUCIA FROM 0.1 MILE SOUTH OF BIG CREEK BRIDGE TO 2.8 MILES SOUTH OF DOLAN CREEK BRIDGE
Sample Information
Sample Taken Date7/7/2016 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing7/11/2016
Sample typeQuality Assurance A brief description of the sample Couplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byAlex Last name of sampler or witnessed byNaime
Title of samplerUnknown Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameDayton Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerDayton Superior Intermediate Assembler or FabricatorUnknown
Rebar Size#7 Coupler ModelBar-Lock
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)A131590 Rebar Heat Number(s)SE16101574
Rebar Size 2 NA
Test Details
DIME Sample ID: 2016-07-07-11
DIME Test ID: 2016-07-07-11-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2016-07-12
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 07/12/2016
UTM: 400KIP
Halo ID: Small
Temperature:72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12C06#7/22mm0.605918198635Service SpliceBrian

General comments (publicly viewable) (Max 250 characters): Service Splice
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 07/12/2016