Summary for Test 2016-05-03-10-3
Test performed: CTM 211-May 2010Project Information
Project Identifiers | Project ID: 210737 DEA: 073X7114 EFIS: 0715000132 |
---|---|
DIST-CO-RTE-PM | 07-LA-60,126-R7.4/R8.1 |
Award Date | 11/16/2015 |
Closeout Date | 06/16/2021 |
Work Description | REALIGN RAMPS, WIDEN BRIDGE, AND REPLACE RAMPS PAVEMENT. |
Location Description | IN LA COUNTY, IN CITY OF MONTEBELLOAT PARAMOUNT BOULEVARD OVERCROSSING |
QA Service Level | 1 (Verified on 12/11/2015) |
Sample Information
Sample Taken Date | 05/03/2016 | Sample Unique Key | 10 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/03/2016 |
Sample type | Annual Source Testing | A brief description of the sample | Three eighths inch PCC Aggregates |
The quantity of what the sample constitutes | 4 Bags | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Unknown | Last name of sampler or witnessed by | Unknown |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | 6159B | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | National Ready Mix Concrete Company | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | SMARA 91 19 0015 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | National Ready Mix Concrete Company |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 3/8 inch |
The concrete mix design number | Lot number | Not set | |
Sublot number | Not set | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2016-05-03-10
DIME Test ID: 2016-05-03-10-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 211-May 2010: Abrasion of Coarse Aggregate by Use of the Los Angeles Abrasion Testing Machine
Test Release Date: 2019-10-15
Test Results
How many revolutions are required?: 500 Revolution Test
Input Type: Calculated
Tester's full name: MD Shahjahan
Date of test: 06/01/2016
Grading: C
Percent wear: 34 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/15/2019 ✔