Test 2016-01-28-9-2 (ASTM C39-17a) Summary

Project Information
Project IdentifiersProject ID: 209950
DEA: 080N56U4
EFIS: 0813000176
DIST-CO-RTE-PM08-SBD-40-R94.7/R99.7
Work DescriptionBRIDGE REPLACEMENTS.
Location DescriptionSAN BERNARDINO COUNTY NEAR ESSEX AT HALLER WASH BRIDGE AT ROJO WASH BRIDGE AND AT CLIPPER VALLEY WASH BRIDGE
Sample Information
Sample Taken Date1/28/2016 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing2/1/2016
Sample typeQuality Control A brief description of the sample6X12
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byJOHN Last name of sampler or witnessed byCARON
Title of samplerUnknown Laboratory sample identification907-16
The fabricator/manufacturer/facility nameROBERTSONS Transportation Laboratory (TL) NumberC012816
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierCLIPPER WASH RT BRIDGE
Structure nameDIAPH A8 B4 B6 AND B7
Material Information
Material TypeConcrete The concrete mix design numberRRM15028
The truck number from where the sample was collected1728 The batch plant ticket number from where the sample was collected1309690
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedLOAD 6 Where the material sample would have been placed if not sampledUnknown
From Lot No.Unknown Bag Lot No.Unknown
Test Details
DIME Sample ID: 2016-01-28-9
DIME Test ID: 2016-01-28-9-2
Testing Lab: CT - Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2016-03-24
Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 03/24/2016
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 190320 lb
Maximum load on cylinder 2: 191100 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 56 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 6732.2 psi
Compressive strength of cylinder 2: 6759.8 psi
Compressive strength (to nearest 10 psi):6750 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 03/24/2016