Summary for Test 2021-09-03-2-1
Test performed: CONCLP 4-16Project Information
Project Identifiers | Project ID: 215589 DEA: 112N0084 EFIS: 1117000153 |
---|---|
DIST-CO-RTE-PM | 11-IMP-7,8,78,86,98,111-Var |
Award Date | 06/25/2021 |
Closeout Date | 09/14/2023 |
Work Description | METHACRYLATE BRIDGE DECKS, REPAIR SPALLS AND REPLACE JOINT SEALS. |
Location Description | IMPERIAL COUNTY AT VARIOUS LOCATIONS. |
QA Service Level | 1 (Verified on 07/06/2021) |
Sample Information
Sample Taken Date | 09/03/2021 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/03/2021 |
Sample type | Authorization | A brief description of the sample | HMWM |
The quantity of what the sample constitutes | 1 Quart Can | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Rob | Last name of sampler or witnessed by | Johnson |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Transpo Industries Inc | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Methacrylate | Mfg. Lot Number(s) | B0722217010 |
---|---|---|---|
Batch number | B0722217010 | Mix number | 3542 |
Test Details
DIME Sample ID: 2021-09-03-2
DIME Test ID: 2021-09-03-2-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 4-16: HMWM
Test Release Date: 2021-09-03
Test Results
Input Type: Calculated
Tester's full name: Spencer Adams
Date of test: 09/03/2021
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F: 27.65
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F: 1.011
Volatile content (ASTM D 2369) 30% max: 43.7
Flash point (ASTM D 3828) more than 180 deg F: 190
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours: no data
Tack free time, 400 minutes max: 499
General comments (publicly viewable) (Max 1000 characters): Bond Strength was not performed due to material failing other tests. Tack Free time went past maximum time of 400 minutes and test was ended at 400 minutes.
Test was verified on 9/3/2021 ✔