Test 2021-08-17-3-3 (ASTM F606-14a) Summary

Project Information
Project IdentifiersProject ID: 88888
DEA: STOCK
EFIS: STOCK
DIST-CO-RTE-PM59---
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
Sample Information
Sample Taken Date8/17/2021 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing8/19/2021
Sample typeStock A brief description of the sample5/8" x 12" DES anchor bolt
The quantity of what the sample constitutes280 From where was the sample collectedManufacturer
First name of sampler or witnessed bySteve Last name of sampler or witnessed byHall
Title of samplerCT METS QA INSPECTOR Laboratory sample identification
The fabricator/manufacturer/facility nameA and M Nut and Bolt Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL134-147-21 Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)N/A
Heat Number(s)2086428 Nut Mfg. Lot Number(s)33883-5804469504
Washer Mfg. Lot Number(s)D9692 Bolt SpecificationF1554 Gr.55
Bolt Length(s)12" Nut SpecificationA194 Gr 2H
Washer SpecificationF436 FinishHDG
Diameter/Size5/8" Bolt Mfg. Lot Number53636-PPO
Rocap Test Requirement(s) Lubricant Requirements(s)
Test Details
DIME Sample ID: 2021-08-17-3
DIME Test ID: 2021-08-17-3-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2021-08-24
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 08/23/2021
UTM:400kip
Temperature:72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11A33883-580446950439646Nut Proof Loadspaine

General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 08/24/2021