Test 2021-05-03-52-1 (CTM 518-June 2010) Summary

Project Information
Project IdentifiersProject ID: 214114
DEA: 040A5394
EFIS: 0418000244
DIST-CO-RTE-PM04-SOL-80,12-11.4/12.8, 2.1/2.8
Work DescriptionWiden EB SR-12 Connector, Construct 3 ramps & 2 box girder bridges, remove existing bridge, etc.
Location DescriptionI-80/I-680/Route 12 Interchange
Sample Information
Sample Taken Date5/3/2021 Sample Unique Key52
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing5/3/2021
Sample typeQuality Control A brief description of the samplePortland Cement Concrete
The quantity of what the sample constitutes100 CY From where was the sample collectedJob Site
First name of sampler or witnessed byMichael Last name of sampler or witnessed byO'Connor
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameSyar Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeConcrete The concrete mix design numberCT063AC5
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected81141576
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedCatch Basin Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.
Test Details
DIME Sample ID: 2021-05-03-52
DIME Test ID: 2021-05-03-52-1
Testing Lab: RMA Group - Rancho Cordova
Test Method: CTM 518-June 2010: Method of Test for Unit Weight of Fresh Concrete
Test Release Date: 2021-08-03
Test Results

Input Type: Calculated
Tester's full name: Michael OConnor
Date of test: 05/03/2021
Calibration factor: 0
Weight of (Measure + Concrete + Cover Plate): 0 lb
Weight of (Measure + Cover Plate): 0 lb
Total weight of cement: 0 lb
Total weight of fine aggregate: 0 lb
Total weight of coarse aggregate: 0 lb
Total weight of water added during mixing: 0 lb
Kelly Ball Penetration of the batch of concrete tested: 0 inch
Air content by the pressure method: 0 %
Station number or portion of the structure in which the concrete was placed: 0
Volume of the concrete: 0 yd^3
Unit weight of the concrete:145 lb/ft^3
Cement content:0 lb/yd^3
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 08/03/2021