Test 2021-07-15-22-2 (AASHTO T315-20) Summary

Project Information
Project IdentifiersProject ID: 215606
DEA: 061C0014
EFIS: 0620000167
DIST-CO-RTE-PM06-MAD-145-8.6
Work DescriptionPARKING LOT RESURFACING WITH COLD PLANE AND HOT MIX ASPHALT.
Location DescriptionMADERA COUNTY IN MADERA AT THE MADERA MAINTENANCE STATION AT 125 WEST ALMOND AVENUE
Sample Information
Sample Taken Date7/15/2021 Sample Unique Key22
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing7/20/2021
Sample typeAcceptance A brief description of the samplePG70-10
The quantity of what the sample constitutes1 OF 1 CAN From where was the sample collectedSource
First name of sampler or witnessed by.unknown Last name of sampler or witnessed by.unknown
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameSan Joaquin Refinery Transportation Laboratory (TL) Number056165
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAsphalt Binder Performance GradePG 70-10
ModifiedNo Lot number1
Sublot number2 Tank number
Time of sample HMA Supplier
Asphalt Binder SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type HMA Design ID
Test Details
DIME Sample ID: 2021-07-15-22
DIME Test ID: 2021-07-15-22-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-07-28
Test Results

Phase: Original binder
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 07/25/2021
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.153 kPa
Phase Angle (δ) (for the 10 cycles): 89.5 degree
Complex Modulus (G*) (for the 10 measurements): 1.273 kPa
Test Temperature: 70.0 C
Dynamic Shear, G*/sin(δ): 1.27 kPa
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications OG

Test was verified on 07/28/2021