Test 2021-06-26-4-1 (AASHTO T240-17) Summary

Project Information
Project IdentifiersProject ID: 215251
DEA: 021J4604
EFIS: 0220000081
DIST-CO-RTE-PM02-SIS-96-34.5/38.8,88.0/92.0
Work DescriptionHMA OVERLAY, REPLACE AC SURFACING, SHOULDER BACKING & TRAFFIC STRIPE.
Location DescriptionSISKIYOU COUNTY NEAR HAPPY CAMP FROM 0.1 MILE EAST OF OAK FLAT CREEK BRIDGE TO 0.1 MILE EAST OF BENJAMIN CREEK ROAD AND FROM 0.3 MILE WEST OF BEAVER CREEK BRIDGE TO 1.0 MILE WEST OF LUMGREY CREEK BRIDGE
Sample Information
Sample Taken Date6/26/2021 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing7/6/2021
Sample typeAcceptance A brief description of the samplePG58-34M
The quantity of what the sample constitutes1 of 1 can From where was the sample collectedManufacturer
First name of sampler or witnessed byD Last name of sampler or witnessed byOwnes
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameValero - Benicia, CA Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAsphalt Binder Performance GradePG 58-34 M
ModifiedYes Lot number
Sublot number Tank number
Time of sample HMA Supplier
Asphalt Binder SupplierValero Marketing & Supply - Benicia CA MultigradeNo
Multigrade Type HMA Design ID
Test Details
DIME Sample ID: 2021-06-26-4
DIME Test ID: 2021-06-26-4-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2021-07-15
Test Results

Is mass change based on one or two containers?: Two
Input Type: Measured
Tester's full name: Harish Thakur
Date of test: 07/14/2021
Any material loss from containers during heating process/testing?: No
Mass of empty container #1: 177.003 grams
Mass of empty container #2: 175.454 grams
Mass of container #1 before test (m1i): 213.104 grams
Mass of container #2 before test (m2i): 210.599 grams
Mass of container #1 after test (m1f): 212.900 grams
Mass of container #2 after test (m2f): 210.406 grams
Average mass change:-0.557 percent
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications

Test was verified on 07/15/2021