Summary for Test 2021-06-21-12-4
Test performed: AASHTO T315-20Project Information
Project Identifiers | Project ID: 212245 DEA: 024F8604 EFIS: 0213000043 |
---|---|
DIST-CO-RTE-PM | 02-TRI-36-26.7/27.1 |
Award Date | 11/02/2018 |
Closeout Date | 05/23/2022 |
Work Description | ROADWAY REALIGNMENT AND NEW BRIDGE CONSTRUCTION |
Location Description | TRINITY COUNTY ABOUT 9 MILES EAST OF FOREST GLEN FROM 0.6 MILE WEST TO 0.1 MILE WEST OF ROUTE 3 |
QA Service Level | 1 (Verified on 03/21/2017) |
Sample Information
Sample Taken Date | 06/21/2021 | Sample Unique Key | 12 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/24/2021 |
Sample type | Acceptance | A brief description of the sample | PG58-34M |
The quantity of what the sample constitutes | 2 cans | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | O | Last name of sampler or witnessed by | V |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | JF Shea - Fawndale | Transportation Laboratory (TL) Number | c823531 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 58-34 M |
---|---|---|---|
Modified | Yes | Lot number | 1 |
Sublot number | 1 | Tank number | |
Time of sample | HMA Supplier | JF Shea - Fawndale | |
Certified Asphalt Supplier | Valero Marketing & Supply - Benicia CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-06-21-12
DIME Test ID: 2021-06-21-12-4
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-06-29
Test Results
Phase: RTFO residue
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 06/28/2021
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 10.00 %
Stress Amplitude: 0.465 kPa
Phase Angle (δ) (for the 10 cycles): 60.4 degree
Complex Modulus (G*) (for the 10 measurements): 4.650 kPa
Test Temperature (Specimen 1): 58.0 C
Dynamic Shear, G*/sin(δ): 5.35 kPa
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications RTFO
Test was verified on 6/29/2021 ✔