Test 2021-05-19-3-4 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 214795
DEA: 030H3424
EFIS: 0317000153
DIST-CO-RTE-PM03-SAC-99-22.6
Work DescriptionREPLACE BRIDGE DECK WITH PRESTRESSED CONCRETE BOX GIRDER.
Location DescriptionSACRAMENTO COUNTY IN SACRAMENTO AT 21ST AVENUE UNDERCROSSING
Sample Information
Sample Taken Date5/19/2021 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing5/20/2021
Sample typeQuality Assurance A brief description of the sample#6 Lenton form savers
The quantity of what the sample constitutes3 lots From where was the sample collectedFabricator
First name of sampler or witnessed byJane Last name of sampler or witnessed byLillard
Title of samplerCALTRANS METS QA INSPECTOR Laboratory sample identification
The fabricator/manufacturer/facility nameConFab Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormS52-019-21 Structure unique identifier24-0154
Structure name21st Ave Undercrossing
Material Information
Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC
Coupler ManufacturerErico Intermediate Assembler or FabricatorPTS Masonry at Confab
Rebar Size#6 Coupler ModelFormsaver
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)Erico heat 201852 lot 9783 and 9809 Rebar Heat Number(s)4105278 4101843
Rebar Size 2 6
Test Details
DIME Sample ID: 2021-05-19-3
DIME Test ID: 2021-05-19-3-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2021-05-20
Test Results

Number of Samples Tested: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 05/20/2021
UTM:400kip
Temperature:72.00 f
Halo ID:Small
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11No. 6/19mm2-0.0030.444155394438Service Splicebewing

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 05/20/2021