Summary for Test 2021-04-28-10-6

Test performed: AASHTO T350-19

Project Information

Project IdentifiersProject ID: 55556
DEA: OCR
EFIS: OCR
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Oregon Corp. Research.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date04/28/2021 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/05/2021
Sample typeProficiency A brief description of the samplePG58V-22
The quantity of what the sample constitutes1 of 1 can From where was the sample collectedSource
First name of sampler or witnessed byN/A Last name of sampler or witnessed byN/A
Title of sampler Telephone number of sampler
Laboratory sample identification313 Linked DIME Sample ID
The fabricator/manufacturer/facility nameMcCall Terminals Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 70-22
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierOregon Corp - Salem OR MultigradeNo
Multigrade TypeNot set Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-04-28-10
DIME Test ID: 2021-04-28-10-6
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T350-19: Multiple Stress Creep Recovery (MSCR) Test of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Multiple Stress Creep Recovery)
Test Release Date: 2021-05-11

Test Results


Input Type: Measured
Tester's full name: Eva Torres
Date of test: 05/10/2021
PG test temperature: 58.0 C
Average percent recovery at 0.1 kPa: 56.0700 %
Average percent recovery at 3.2 kPa: 40.6600 %
Nonrecoverable creep compliance: 0.2088
Nonrecoverable creep compliance: 0.2977
Percent difference between nonrecoverable creep compliance at 0.1 kPa and 3.2 kPa: 42.5700 %
General comments (publicly viewable) (Max 1000 characters): MSCR - 1st

Test was verified on 5/11/2021