Test 2021-04-15-14-2 (AASHTO T335-09r13) Summary

Project Information
Project IdentifiersProject ID: 215359
DEA: 081K1904
EFIS: 0818000207
DIST-CO-RTE-PM08-SBD-15-16.1/169.4
Work DescriptionREMOVE, PREPARE AND FURNISH POLYESTER CONC OVERLAY & BRIDGE DECK.
Location DescriptionSAN BERNARDINO COUNTY IN AND NEAR HESPERIA AT VARIOUS LOCATIONS FROM CAJON CREEK TO MICRO DITCH.
Sample Information
Sample Taken Date4/15/2021 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing4/16/2021
Sample typeVerification A brief description of the sampleJMF 3/4" HMA-A-SP R15 1.0% LSM
The quantity of what the sample constitutes11 Bags of Virgin, 3 Bags of Coldfeed, 2 Bags of RAP From where was the sample collectedManufacturer
First name of sampler or witnessed byBlue Diamond Materials Victorville Last name of sampler or witnessed byQC
Title of sampler Laboratory sample identification0226A-21
The fabricator/manufacturer/facility nameBlue Diamond Victorville Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-36-0046, 91-36-0106
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R15 The fabricator/manufacturer designation for the sample
The plant number300154 LSM A detailed description of where the material sample was collectedBelt Cut at Blue Diamond Victorville Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number JMF Verification ID
Test Details
DIME Sample ID: 2021-04-15-14
DIME Test ID: 2021-04-15-14-2
Testing Lab: CT - Southern Regional Laboratory
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Test Release Date: 2021-04-30
Test Results

Method: 1 - Combined Fracture Determination
Aggregate Size and Fracture Type: Coarse 1 and 2 Faced and Fine 1 Faced
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 04/25/2021
Percentage of fractured, coarse, 2 faced particles tested:96 %
Percentage of fractured, coarse, 1 faced particles tested:98 %
Percentage of fractured, fine, 1 faced particles tested:100 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 04/30/2021