Test 2020-11-09-36-2 (CTM 214-August 2010) Summary

Project Information
Project IdentifiersProject ID: 213732
DEA: 044K1104
EFIS: 0417000260
DIST-CO-RTE-PM04-SF-1-R0.0/0.9,R4.0/6.9
Work DescriptionREHABILITATE ROADWAY AND REPLACE SIGNALS.
Location DescriptionTHE CITY AND COUNTY OF SAN FRANCISCO FROM SAN MATEO COUNTY LINE TO HOLLOWAY AVENUE AND FROM LINCOLN WAY TO RUCKMAN AVENUE UNDERCROSSING
Sample Information
Sample Taken Date11/9/2020 Sample Unique Key36
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing4/1/2021
Sample typeAnnual Source Testing A brief description of the sampleFine
The quantity of what the sample constitutes1 bag From where was the sample collectedSource
First name of sampler or witnessed byB Last name of sampler or witnessed bySingh
Title of samplerConsultant Laboratory sample identification21-PCCF-0053
The fabricator/manufacturer/facility nameHanson Sunol Transportation Laboratory (TL) NumberC934617
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-01-0011
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedplant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Sizefine
The concrete mix design number Lot number
Sublot number HMA Design ID
Test Details
DIME Sample ID: 2020-11-09-36
DIME Test ID: 2020-11-09-36-2
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium Sulfate
Test Release Date: 2021-04-16
Test Results

What size aggregate is being tested?: Fine Aggregate
Input Type: Calculated
Tester's full name: Ryan Kester/ Jay Horton
Date of test: 04/16/2021
Percentage Loss of material retained on #8 sieve: no data
Percentage Loss of material retained on #16 sieve: no data
Percentage Loss of material retained on #30 sieve: no data
Percentage Loss of material retained on #50 sieve: no data
Percentage Loss of material retained on #100 sieve: no data
Weighted Average Percent Loss of Fine Aggregate:4.4 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 04/16/2021