Test 2021-03-18-5-4 (AASHTO T84-14) Summary

Project Information
Project IdentifiersProject ID: 214821
DEA: 120H1504
EFIS: 1216000055
DIST-CO-RTE-PM12-ORA-1-4.9/5.5,10.5/14.1
Work DescriptionCold plane AC, RHMA-G paving, and curb ramp reconstruction
Location DescriptionORANGE COUNTY IN LAGUNA BEACH AND NEWPORT BEACH FROM 0.2 MILE SOUTH OF VISTA DEL SOL TO 7TH AVENUE AND FROM LEDROIT STREET TO NEWPORT COAST DRIVE
Sample Information
Sample Taken Date3/18/2021 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing3/22/2021
Sample typeVerification A brief description of the samplePSUE 3/4" WMA-A-SP R25, 0.25% EVO
The quantity of what the sample constitutes3 Bags of Coldfeed Aggegate From where was the sample collectedManufacturer
First name of sampler or witnessed byRJ Noble Orange Last name of sampler or witnessed byQC
Title of sampler Laboratory sample identification0165A-21
The fabricator/manufacturer/facility nameRJ Noble Orange Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-33-0035
The fabricator's/manufacturer's product name for the sample3/4 WMA-A-SP The fabricator/manufacturer designation for the sample
The plant number36R2508SPWEO A detailed description of where the material sample was collectedBelt Cut at RJ Noble Orange Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number JMF Verification ID
Test Details
DIME Sample ID: 2021-03-18-5
DIME Test ID: 2021-03-18-5-4
Testing Lab: CT - Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2021-03-29
Test Results

Input Type: Measured
Tester's full name: Danilo Ferrer
Date of test: 03/25/2021
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 989.1 grams
Mass of the pycnometer with water (B): 674.7 grams
Mass of the oven dried sample (before pycnometer) (A): 492.6 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 492.6 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity:2.654
Bulk specific gravity (SSD Basis):2.694
Apparent specific gravity:2.764
Absorption:1.5 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 03/29/2021