Test 2020-08-10-47-3 (AASHTO T209-12) Summary

Project Information
Project IdentifiersProject ID: 214618
DEA: 033F99U4
EFIS: 0319000311
DIST-CO-RTE-PM03-SUT-99-39.2/41.4
Work DescriptionWIDEN RDWY, HMA, CRCP, WATER LINE, SIGNALS, & LIGHTING SYSTEM.
Location DescriptionSUTTER COUNTY IN AND NEAR LIVE OAK FROM 0.1 MILE SOUTH OF COLEMAN AVENUE TO NEVADA STREET (NORTH INTERSECTION)
Sample Information
Sample Taken Date8/10/2020 Sample Unique Key47
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing8/11/2021
Sample typeVerification A brief description of the sample3/4 inch RHMA-G
The quantity of what the sample constitutesJMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byBrad Last name of sampler or witnessed byMckeehan (WITNESS)
Title of samplerDGS Personnel Laboratory sample identificationJMF20-030B
The fabricator/manufacturer/facility nameDSG Aggregates - Marysville Transportation Laboratory (TL) NumberC 779832
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading3/4 inch Lot number
Sublot number JMF Verification ID JMF3513-2021-27
Test Details
DIME Sample ID: 2020-08-10-47
DIME Test ID: 2020-08-10-47-3
Testing Lab: CT D03 - North Region Materials Lab
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2021-02-25
Test Results

Number of tests: 1
Mass Determination: Air
Input Type: Measured
Tester's full name: Kavon Rastegar
Date of test: 08/24/2020
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7346.6 grams
Mass of oven-dry sample in air for Sample 1: 2153.1 grams
Mass of container filled with the sample and water for Sample 1: 8635.2 grams
Temperature of Water: 76 °F
Specific Gravity for Sample 1: 2.491
General comments (publicly viewable) (Max 1000 characters): JMF20-030B. Report Only.