Test 2021-02-09-5-2 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 214579
DEA: 010B0904
EFIS: 0100020444
DIST-CO-RTE-PM01-DN-101-8.2/8.7
Work DescriptionBRIDGE REPLACEMENT
Location DescriptionDEL NORTE COUNTY NEAR KLAMATH AT PANTHER CREEK BRIDGE AND AT HUNTER CREEK BRIDGE
Sample Information
Sample Taken Date2/9/2021 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing2/16/2021
Sample typeQuality Assurance A brief description of the sample(1500) #5 1'-6" Ø Ultimate Welded Hoops QA Sample
The quantity of what the sample constitutes(4) #5 1'-6" Ø Ultimate Welded Hoops QA Samples Lot 20 From where was the sample collectedFabricator
First name of sampler or witnessed byRigoberto Last name of sampler or witnessed byMarin
Title of samplerQAI Laboratory sample identification
The fabricator/manufacturer/facility nameTNT Rebar Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL133-011-21 Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4103179
Hoop Manufacturer Lot Number(s)Lot 20 Material Standard CodeASTM A706
Material Grade60 Rebar Size#5
Diameter of Hoop1'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Arizona
Welding CompanyTNT Rebar Corp Coating StandardsUncoated
Weld TypeFlash Welded
Test Details
DIME Sample ID: 2021-02-09-5
DIME Test ID: 2021-02-09-5-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2021-02-17
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 02/17/2021
UTM:400kip
Temperature:72 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12205/16mm0.3129500.1295162OK Neckingfsaylor

General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 02/17/2021