Summary for Test 2020-12-11-13-1
Test performed: CONCLP 4-16Project Information
Project Identifiers | Project ID: 212914 DEA: 031E0604 EFIS: 0312000068 |
---|---|
DIST-CO-RTE-PM | 03-YUB-70-15.5/16.5 |
Award Date | 07/31/2019 |
Closeout Date | 08/30/2023 |
Work Description | SIMMERLY SLOUGH BRIDGE REPLACEMENT BR 16-0019 WITH BR 16-0055. |
Location Description | NEAR MARYSVILLE, FROM 0.1 MILE NORTH OF BINNEY JUNCTION UNDERPASS TO 0.3 MILE NORTH OF LAURELLEN ROAD, AT SIMMERLY SLOUGH BRIDGE BR 16-0019. |
QA Service Level | 1 (Verified on 08/22/2019) |
Sample Information
Sample Taken Date | 12/11/2020 | Sample Unique Key | 13 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/11/2020 |
Sample type | Quality Assurance | A brief description of the sample | 1 gallon can |
The quantity of what the sample constitutes | 1 gallon can | From where was the sample collected | Source |
First name of sampler or witnessed by | Daniel | Last name of sampler or witnessed by | Tikusis |
Title of sampler | Telephone number of sampler | 707-330-9227 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Kwik Bond | Transportation Laboratory (TL) Number | C631501 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Methacrylate | Mfg. Lot Number(s) | 20-40-390489 |
---|---|---|---|
Batch number | 2040390489 | Mix number | 2040390489 |
Test Details
DIME Sample ID: 2020-12-11-13
DIME Test ID: 2020-12-11-13-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 4-16: HMWM
Test Release Date: 2021-07-22
Test Results
Input Type: Measured
Tester's full name: Phillip Montes
Date of test: 12/24/2020
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F: 20.6
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F: 1.10
Volatile content (ASTM D 2369) 30% max: 17.8
Flash point (ASTM D 3828) more than 180 deg F: 201
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours: 872
Tack free time, 400 minutes max: 340
General comments (publicly viewable) (Max 1000 characters): Accepted vendor results for D2369, CTM 551 and tack free time.
Test was verified on 7/22/2021 ✔